7.
RF & Microwave Power Amplifier/ 微波功率放大器
 
1.0 TO 18.0 GHz MODELS

TWTA Power
Output
(watts/min.)

Frequency

Gain at Rated
Power1
(dB/min.)

TWTA Model
Number

RF Connector
Input/Output

TWT Model
Number

10

Standard Bands

1.0 to 2.0

30

8010H09*000

N

417HD

2.0 to 4.0

30

8010H01*000

N

564H

4.0 to 8.0

30

8010h02*000

N

648HD

8.0 to 12.4

30

8010H03*000

N

771HD

12.4 to 18.0

30

8010H04*000

N

848HD

Multibands

3.0 to 8.0

30

8010H13*000

N

646H

3.9 to 11.72

30

8010H16*000

N

664H

8.0 to 18.0

30

8010H15*000

N

846H

20

Standard Bands

1.0 to 2.0

30

8020H09*000

N

418H

2.0 to 4.0

30

8020H01*000

N

568H

4.0 to 8.0

35

8020H02*000

N

640H

8.0 to 12.4

35

8020H03*000

N

783H

12.4 to 18.0

35

8020H04*000

N/UG419

856H

Multibands

1.4 to 2.4

30

8020H10*000

N

419H

8.0 to 18.0

30

8020H15*000

N

889HB

30

4.0 to 8.0

30

8030H02*000

N

670HB

 

SPECIFICATIONS(1) 8000H/D Series

RF Performance

Duty

CW

Noise Figure

35 dB typical

Spurious Modulation

50 dBc max

Load VSWR

2.5:1 max (5)

Gain Stability

0.25 dB/24 hours (2)

Electrical Input Voltage

99 to 132 VAC, 47 to 63 Hz

Power Consumption

8001H.....115 watts (3)
8010H......250 watts (3)
8020H......280 watts (3)
8030H......350 watts (3)
8040D......450 watts (3)
8060D......600 watts (3)
8070D......900 watts (3)

Mechanical

Size/Configuration

(see Outline Drawing)

Weight

3.5-inch chassis height versions

20 pounds (9.1 kg) max

7-inch chassis height versions

50 pounds (22.7 kg) max

Cooling (integral blower)

forced air

 

RF Connector Type

(see table: 1.0 to 18.0 GHz Models, 18.0 to 45.0 GHz Models)

Environmenta

Temperature (operating)

0 to +50 °C

Relative Humidity (without condensation)

95% max

Altitude

10,000 feet max4

Shock and Vibration

as normally encountered in
commercial shipping and handling

Warranty

One full year - no hour limit
Footnotes:
(1) Specifications subject to change without notice.
(2) At constant drive and temperature after warm-up period.
(3) Indicates max power consumption of any model in that power range. For information on specific models, consult the factory.
(4) 40¡ÆC max operating temperature above 6,000 feet.
(5) Option J allows operation at higher system VSWRs.